ȯ¿µÇÕ´Ï´Ù.
Àüµ¿µå¶óÀ̹ö-Åä¿ÀÄÚ¸ÞŸ
Àεαâ
¿¡¾î´ÏÆÛ/Àü±â´ÏÆÛ
¾ÐÂø±â
ÀúÇ×Æ÷¹Ö±â
³³/³³°ÉÀÌ/½ºÆùÁö/WICK
PCBıÆñâ/¸®µåıŸ/¿¬¸¶±â
³ª»ç°ø±Þ±â ½ºÇÁ¸µ¹Ù¶õ½º
ÃÊÀ½Æļ¼Ã´±â
ÇÚµåÇÁ·¹½º
â°íÁ¤¸® -Àç°íó¸®
Á¤Àü±âÁ¦Ç°
µðÇαâ/³³¿¬±âÁ¦°Å±â
¿¡¾îµå¶óÀ̹ö
Å×½ºÅͱâ/µðÁöÅ»¿Âµµ°è
ÀεÎÆÁ/È÷Ÿ/½ºÅÙµå/NUT
¿­Ç³±âICÁ¦°Å/ÀÚµ¿ÈíÀÔ±â
¿¡¾î(Àüµ¿)ºñÆ®
ÇɼÂ/ÈíÀÔ±â
Å×ÀÌÇÁ/¸ÖƼ°ï¼¾Æ®/ ŸÀÌ
¿­Ç³±â/±Û·ç°Ç
´ÏÆÛ/ÃÊ°æ´ÏÆÛ/ıŸ
Çö¹Ì°æ/È®´ë°æ
¼±Ç³±â
¿øÀû¿Ü¼±È÷Ÿ
½Å±ÔÇ°¸ñ
µå¶óÀ̹ö/¼¼¶ó¹Í/Á¶Á¤ºÀ
ÈĶô½º/Ç÷°½º/Å©¸²¼Ö´Ù ·¹Çαâ
*ÇÑÁ¤»óÇ°*
º¹½ºµå¶óÀ̹ö/¼¼Æ®·ù
½ºÆ®¸³ÆÛ/Àý´Ü°¡À§
·¡ÇÎ ¿ÍÀ̾î
Ź»ó¿ë|¹Ì´Ïµå¸±/µå¸±³¯
Ådz¯/ÁÙ/¼¼Æ®·ù
Ä®/Åé/¸ÁÄ¡·ù
°ø±¸¼¼Æ®/°¡¹æ/¹Ú½º
ºÎÇ°¹Ú½º/Äɺñ³Ý
Àüµ¿°ø±¸
¿ëÁ¢±â
¾ÈÀü¿ëÇ°
ELECTROLUBE
HOZAN
·£ÅÏ/°¡½ºÅäÄ¡ ¼öÀÔÁ¦Ç°
À°°¢·»Áö
ATOM
·¹ÀÌÁ®·¹º§±â
DONGYANG
ÀüÀÚÀú¿ï
ÃøÁ¤°ø±¸
ÃøÁ¤±â±â/°èÃø±â
Àý´Ü¼®/¿¬¸¶¼®
µî»ê/Ä·Çοë
µ¸º¸±â
µðÁöÅÐ.¾Æ³ª·Î±× Ķ¸®ÆÛ½º
Ä«µå°áÁ¦
»óÇ°¹®ÀÇ°Ô½ÃÆÇ
°í°´°Ô½ÃÆÇ
 
757,351¸í
0¸í
0¸í
 

HOME > Å×½ºÅͱâ/µðÁöÅ»¿Âµµ°è > FLUKE
FLUKE
¢Ã KYORITSU
¢Ã HIOKI
¢Ã »ï±¤
¢Ã Protek
¢Ã METEX
¢Ã FLUKE
¢Ã ±âŸ
¢Ã CEM
¢Ã Äڳؽº
¢Ã Ÿ½ºÄÚ
¢Ã YOKOGAWA
¢Ã ű¤ÀüÀÚ
¢Ã »õÇÑ°è±â
¢Ã ASAHI
¢Ã UNI-T
¢Ã ARCO
¢Ã DADA
¢Ã DONGYANG
¢Ã TES
¢Ã SANWA
¢Ã RPOVA
¢Ã Èïâ
¢Ã MiNipro
¢Ã MANIA
¢Ã SATO
¢Ã PRONIA
¢Ã Q.T
¢Ã AMPROBE
¢Ã TOYOTECH
¢Ã ICMANIA
¢Ã KEYSIGHT
FLUKE-355 AC 1400A, DC 2000A[1ÀÏ][ºÎ°¡¼¼º°µµ]
Á¦ Á¶ »ç : FLUKE ¹Ì±¹
¸ð µ¨ ¸í : FLUKE-355
¼ÒºñÀÚ°¡ : 1,500,000¿ø
: 1,374,000¿ø
Æ÷ ÀÎ Æ® : 0¿ø
±¸ÀÔ¼ö·® : °³
 
Fluke-355/353 2000A Ŭ·¥ÇÁ¹ÌÅÍ

°í-Àü·ù ÃøÁ¤±â´É°ú Ä¿´Ù¶õ Áý°Ô¸¦ °¡Áö°í ÀÖ¾î »ê¾÷ ºÐ¾ß ¹× ¼³ºñ ¾îÇø®ÄÉÀ̼ǿ¡ ÀûÇÕÇÏ°Ô µðÀÚÀÎµÈ Å¬·¥ÇÁ¹ÌÅÍÀÔ´Ï´Ù.
Ture-RMS·Î ½Å·Ú¼º ÀÖ´Â ÃøÁ¤ÀÌ °¡´ÉÇÑ Fluke 355/353 Ŭ·¥ÇÁ¹ÌÅÍ´Â 2000A±îÁöÀÇ Àü·ù ÃøÁ¤À» À§ÇØ ¼±ÅÃÇÒ ¼ö ÀÖ´Â ÀåºñÀÔ´Ï´Ù.
ÀϹÝÀûÀ¸·Î °í-Àü·ù ¾îÇø®ÄÉÀ̼ǿ¡¼­ ¹ß°ßÇÒ ¼ö ÀÖ´Â ±½Àº ÄÉÀÌºíµµ ½±°Ô ÃøÁ¤ÇÒ ¼ö ÀÖµµ·Ï Ä¿´Ù¶õ Àåºñ¸¦ °¡Áö°í ÀÖ½À´Ï´Ù.
¶ÇÇÑ, °í-Àü·ÂÀ» ÃøÁ¤ÇÒ ¶§ »ç¿ëÀÚ º¸È£¸¦ À§ÇÑ °ß°íÇÑ µðÀÚÀΰú CAT IV 600V, CAT III 1000V ¾ÈÀü µî±ÞÀÌ Æ¯º°È÷ Ãß°¡µÇ¾ú½À´Ï´Ù. 

Ư¡
- 2000A ac+dc true-rms, 1400A ac, 2000A dc·Î ½Å·Ú¼º ÀÖ°Ô ÃøÁ¤
- 50mmÀÇ Å« Áý°Ô·Î Å©°í ´Ù¾çÇÑ ÄÉÀÌºí¿¡ ÀûÇÕ
- »ç¿ëÀÚ º¸È£¸¦ À§ÇÑ CAT IV 600, CAT III 1000V ¾ÈÀüµî±Þ
- ÃÖ¼Ò, ÃÖ´ë, Æò±Õ ±â´É
- µð½ºÇ÷¹ÀÌ È¦µå ±â´É


Electrical specifications
Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 A Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 §Ù Resolution: 0.1 §Ù
Accuracy: 1.5 % + 5 digits
Range: 4 k§Ù Resolution: 1 §Ù
Accuracy: 1.5 % + 5 digits
Range: 40 k§Ù Resolution: 10 §Ù
Accuracy: 1.5 % + 5 digits
Range: 400 k§Ù Resolution: 100 §Ù
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)
  On at ¡Â 30 §Ù
  Off at ¡Ã 100 §Ù
Frequency measurement
Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger level Refer to current and voltage tables

*Add 2 % to error spec for CF > 2
 
 
µî·ÏÀÚ  
±ÛÁ¦¸ñ
³» ¿ë 
ºñ¹Ð¹øÈ£  (4ÀÚÀÌ»ó 12ÀÚÀÌÇÏ/¿µ¹® ¹×¼ýÀÚ Á¶ÇÕ)
 
   
(ÁÖ)µ¿¾ç°ø±¸ [º»»ç]¼­¿ï ±Ýõ±¸ ½ÃÈï3µ¿ À¯Åë»ó°¡ 27µ¿ 121È£-A/Sµî ¹ß¼ÛÁÖ¼Ò
[ÁöÁ¡] ¼­¿ïƯº°½Ã ±Ýõ±¸ ½ÃÈï´ë·Î 97. 27µ¿121È£(½ÃÈﵿ,½ÃÈïÀ¯Åë»ó°¡) | ´ëÇ¥ÀÚ : À̵µÇü
ÀüÈ­¹øÈ£ : 02-896-8860 | FAX : 02-894-0943 | Á¤º¸Ã¥ÀÓ´ã´çÀÚ : °ü¸®ÀÚ
°øÁ¤°Å·¡À§¿øȸ °í½Ã Á¦ 2000-1È£¿¡ µû¸¥ »ç¾÷ÀÚ µî·Ï¹øÈ£ ¾È³» : 124-87-52182
Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2017-0171È£ | E-mail : dy09@dy09.co.kr

Copyright (c) 2024 (ÁÖ)µ¿¾ç°ø±¸, All rights reserved. Mail to Webmaster
ÀÎÁõ¸¶Å©