PROVA-6600 3 Phase/1 Phase Power Clamp
|
- 3 f 4W, 3 f 3W, 3 f Balanced, 1 f 2W, and 1 f 3W Power
Measurement.
- AC+DC true power, and True RMS AC Voltage and Current
- AC+DC 2000A, AC 600V, DC 800V
- AC+DC 1200KW(1 f ), AC+DC 2000KW (3 f )
- Dual Display V+Hz, A+Hz, W+PF, KVA+KVAR, V+A
- Phase Angle Measurement
- 3 f RST(L1L2L3) Sequence Indication.
- Memory of 4 records.
- DCA/DCW Auto Zero when power clamp powering on.
- AC/DC Auto Detection.
- Auto range.
|
AC+DC True Power (PF 0.2-1.0, 3 ¥Õ 3W, 3 ¥Õ 4W, 1 ¥Õ 2W,
and 1 ¥Õ 3W) |
Range
|
Resolution
|
Accuracy(of rdg)
|
Input Range
|
0-99.9KW
|
0.1KW
|
+/- 2.0% +/- 0.05KW
|
AC 600V, DC 800V, ACA/DCA 2000A
|
100-999.9KW
|
0.1KW
|
+/- 2.0% +/- 0.5KW
|
AC 600V, DC 800V, ACA/DCA 2000A
|
1000-1200KW
|
1KW
|
+/- 2.0% +/- 5KW
|
AC 600V, DC 800V, ACA/DCA 2000A
|
|
AC+DC True Power (Power Factor 0.2-1.0, 3 ¥Õ Balanced
Power) |
Range
|
Resolution
|
Accuracy (or rdg)
|
Input Range
|
0-99.99KW
|
0.01KW
|
+/- 2.0% +/- 0.5KW
|
AC 600V, DC 800V, ACA/DCA 2000A
|
100-999.9KW
|
0.1KW
|
+/- 2.0% +/- 0.5KW
|
AC 600V, DC 800V, ACA/DCA 2000A
|
1000-1200KW
|
1KW
|
+/- 2.0% +/- 5KW
|
AC 600V, DC 800V, ACA/DCA 2000A
|
POWER FACTOR (PF)
PF=KW/KVA
|
|
AC+DC Voltage (True RMS, Crest Factor<4, Autorange,
Overload Protection 800VAC for all ranges) |
Range
|
Resolution
|
Accuracy(of reading)
|
Input Impedance
|
DC, 50/60Hz
|
40-400Hz
|
0-200A
|
0.1V
|
+/- 1.5% +/- 5 dgts
|
+/- 2.0% +/- 5 dgts
|
10M ¥Ø
|
200-500A
|
0.1V
|
+/- 1.5% +/- 5 dgts
|
+/- 2.0% +/- 5 dgts
|
10M ¥Ø
|
500-600VAC
500-800VDC
|
1V
|
+/- 1.5% +/- 5 dgts
|
+/- 2.0% +/- 5 dgts
|
10M ¥Ø
|
|
AC+DC Current (True RMS, Crest Factor<4) |
Range
|
Resolution
|
Accuracy(of reading)
|
Overload Protection
|
DC, 50/60 Hz
|
40-400Hz
|
0-200A
|
0.1A
|
+/- 1.5% +/- 5 dgts
|
+/- 2.0% +/- 5 dgts
|
AC 3000A
|
200-500A
|
0.1A
|
+/- 2.0% +/- 5 dgts
|
+/- 2.5% +/- 5 dgts
|
AC 3000A
|
500-2000A
|
1A
|
+/- 2.5% +/- 5 dgts
|
+/- 3.0% +/- 5 dgts
|
AC 3000A
|
AC+DC KVA (Apparent Power)
(KVA)=VxA/1000
AC+DC KVAR (Reactive Power)
(KVAR)=
|
|
Phase Angle (must zero current reading before
measurement) |
Range
|
Accuracy
|
Sensitivity
|
Remark
|
50/60Hz
|
+/- 2.0 ¡Æ
|
V>100V, A>10A
|
Zero Crossing Detection
|
|
Frequency (if<10 Hz, Hz=0) |
Range
|
Accuracy
|
Sensitivity
|
50/60Hz
|
+/- 2dgts
|
V: >1V, A: >5A
|
10-400Hz
|
+/- 0.5% +/- 2dgts
|
V: >1A, A: >5A
|
|
Conductor
Size |
Cable f 55mm. (approx.)
Bus Bar 65mm(D)x24mm(W) |
Battery
Type |
9V |
Display |
2x4 Digits Dual Display LCD |
Range
Selection |
Auto |
Overload
Indication |
OL |
Power
Consumption |
28mA (approx.) |
Low
battery Indication |
|
Sampling
Time |
0.5 sec. (V and A)
1.6 sec. (W) |
Operating
Temperature |
4 o to 50 o C |
Operating
Humidity |
Less than 85% relative |
Altitude |
up to 2000M |
Storage
Temperature |
-20 o C to 60 o |
Storage
Humidity |
Less than 75% relative |
Dimensions |
271mm(L)x112mm(W)x46mm(H)
10.7"(L)x4.4"(W)x1.8"(H) |
Weight |
647g/22.8 oz (Battery included) |
|
|
|