PROVA-5601/5637 Clamp-on Ground Resistance
Tester
|
- Non-Contact Ground Resistance Measurement
- No Auxiliary Electrode Needed
- Jaw Diameter ¥Õ 23 mm (5601)
- Jaw Diameter ¥Õ 35 mm(5637)
- 0.025 – 1500 Ohm
|
- 0.2mA– 30A(5601)0.2mA– 35A(5637),True RMS
- 116 Sets of Memory(5601,5637)
- Programmable Hi and Lo Alarm(5601,5637)
- Programmable Data Logging (5601,5637)
|
- Telecommunication
- Cable TV system
- Electrical Power Plant
|
- Cellular Phone System
- Factory and Facility
- Gas Station Tank
|
Ground Resistance (Auto range) |
Range
|
Resolution
|
Accuracy of Reading 1,2
|
0.025 - 0.250 ¥Ø
|
0.002 ¥Ø
|
¡¾ 1.5% ¡¾ 0.05 ¥Ø
|
0.250 - 1.000 ¥Ø
|
0.02 ¥Ø
|
¡¾ 1.5% ¡¾ 0.05 ¥Ø
|
1.001 - 9.999 ¥Ø
|
0.02 ¥Ø
|
¡¾ 1.5% ¡¾ 0.1 ¥Ø
|
10.00 - 50.00 ¥Ø
|
0.04 ¥Ø
|
¡¾ 2.0% ¡¾ 0.3 ¥Ø
|
50.01 - 99.99 ¥Ø
|
0.04 ¥Ø
|
¡¾ 2.0% ¡¾ 0.5 ¥Ø
|
100.0 - 200.0 ¥Ø
|
0.4 ¥Ø
|
¡¾ 3.0% ¡¾ 1.0 ¥Ø
|
200.1 - 400.0 ¥Ø
|
2 ¥Ø
|
¡¾ 5.0% ¡¾ 5 ¥Ø
|
400.1 - 600.0 ¥Ø
|
5 ¥Ø
|
¡¾ 10% ¡¾ 10 ¥Ø
|
600.1 - 1500 ¥Ø
|
20 ¥Ø
|
¡¾ 20%
|
1 Loop resistance noninductive,
external field < 200 A/m, external electrical field
< 1 V/m, conductor centered.
2 Resistance Measurement Frequency:
1.667KHz,3.333KHz(optional)
|
|
Ground/Leakage Current (Auto range, 50/60 Hz, True RMS,
Crest Factor < 3.5) |
Range
|
Resolution
|
Accuracy of Reading
|
0.200 - 1.000 mA
|
0.001 mA
|
¡¾ 2.0% ¡¾ 0.05 mA
|
1.00 - 10.00 mA
|
0.01 mA
|
¡¾ 2.0% ¡¾ 0.03 mA
|
10.0 - 100.0 mA
|
0.1 mA
|
¡¾ 2.0% ¡¾ 0.3 mA
|
100 - 1000 mA
|
1 mA
|
¡¾ 2.0% ¡¾ 3 mA
|
0.20 - 4.00 A
|
0.001A
|
¡¾ 2.0% ¡¾ 0.03A
|
4.00 - 30.00 A(5601)
|
0.01A
|
¡¾ 3.0% ¡¾ 0.03A
|
4.00 - 35.00 A(5637)
|
0.01A
|
¡¾ 3.0% ¡¾ 0.03A
|
|
Accuracy
of Resistance Calibration Plate |
¡¾0.5% |
Data
Logging Capacity |
116 records |
Data
Logging Interval |
1 to 255 seconds |
Conductor
Size |
35mm /1.38¡±(5637), 23mm
/0.90¡±(5600,5601) |
Jaw
Opening |
38mm /1.49¡±(5637), 27mm
/1.06¡±(5600,5601) |
Battery
Type |
9V IEC 6 LR61 (Alkaline) |
Display
Type |
4 digits 9999 counts LCD |
Overload
Indication |
OL |
Battery
Life |
3000 measurements |
Low
Battery Indication |
¡¡ |
Range
Selection |
Auto |
Power
Consumption |
40mA |
Sampling
Time |
0.5 seconds |
Operating
Temperature |
0 ¡É to 50 ¡É (14 ¢µ to 122 ¢µ )
Operating Humidity: Less than 85% RH |
Storage
Temperature |
-20 ¡É to 60 ¡É (-4 ¢µ to 122 ¢µ )
Storage Humidity: Less than 75% RH |
Dimension(
5637 |
276mm (L) x 100mm(W) x 47mm(H),10.8" (L) x
3.9"(W) x 1.9"(H) |
Dimension(
5600,5601 ) |
257mm (L) x 100mm(W) x 47mm(H),10.1" (L) x
3.9"(W) x 1.9"(H) |
Weight(
5637) |
750g/1.65lbs |
Weight(
5600,5601) |
640g/1.41lbs |
Accessories |
- Resistance Calibration Plate x 1
- Battery 9V (Installed) x 1
- Carrying Box x 1
- Users Manual x 1
|
|
|
|
|
|
|
|
|
|
|
|